Cooper & Hunter | Hyper Outdoor Series
Model: CH-RHP60LCU-230VO
BTU
54,000
SEER2
18
Voltage
208-230V, 1Ph, 60Hz V, Ph, Hz
Refrigerant
R454B
Indoor: CH-RSH60LCFC
Cooper&Hunter's 60K BTU, 230V Hyper Single-Zone Outdoor Unit is the epitome of powerful and energy-efficient performance, perfectly suited for expansive residential properties and light commercial settings. Utilizing cutting-edge inverter technology, this unit seamlessly adjusts compressor speed to align with specific heating and cooling demands, ensuring precise temperature control while optimizing energy consumption for long-term cost savings. The Hyper series stands out with its enhanced Hyper Heating functionality, which guarantees dependable operation even in extreme cold, maintaining warmth in temperatures as low as -22°F. Its use of R454B refrigerant underscores an eco-friendly approach, offering a reduced Global Warming Potential (GWP) and reinforcing Cooper&Hunter's dedication to environmental sustainability. Built for resilience, the 60K BTU Hyper unit is designed to withstand harsh conditions and deliver reliable performance year-round. With an impressive SEER2 rating of up to 18, it combines robust construction with whisper-quiet operation, making it an excellent solution for both residential and light commercial environments. This unit seamlessly integrates innovation, durability, and energy efficiency for superior climate control.
| Indoor Model | CH-RSH60LCFC |
| Power supply | 208-230V, 1Ph, 60Hz V, Ph, Hz |
| Communication wiring | AWG 14-3 |
| Cooling Capacity | 54,000 (20,000~54,500) Btu/h |
| Input | 85 w |
| Rated current | 26.1 (6.7~26.1) A |
| Heating at 47 °F Capacity | 60,000 (21,700~65,500) Btu/h |
| COP | 03.02 W/W |
| HSPF4/HSPF2-4 | 10.7 |
| HSPF5/HSPF2-5 | 8.5 |
| Indoor fan motor | 2 Qty |
| Indoor air flow (Turbo/Hi/Med/Lo) (No duct) | 1,365.6 / 1,236.1 / 1,118.3 / 882.9 CFM |
| ESP (range) | / ln.wg. |
| Indoor noise level (Hi/Med/Lo) | 54.5/49/42 dB(A) |
| Dehumidification | 15.14 L/H |
| Indoor unit Dimensions (WxDxH) | 64.96 x 26.57 x 9.25 inch |
| Packing (WxDxH) | 43.11 x 19.49 x 57.48 inch |
| Net/Gross weight | 208.78/239.86 inch |
| Drainage water pipe diameter | 1" inch |
| Refrigerant piping (Liquid side/Gas side) | 3/8"/3/4" inch |
| Design pressure | 550/340 PSIG |
| Controller | remote controller |
| Room temperature Cooling | 60~90 F |
| Heating | -22~75 F |
| Outdoor Model | CH-RHP60LCU-230VO |
| Min. circuit ampacity | 44 A |
| Max. fuse | 45 A |
| Compressor Model | EKPQ440D1UMUB |
| Type | TWIN-ROTARY |
| Brand | GMCC |
| Capacity | 42.78 Btu/h |
| Rated current (RLA) | 26.8 A |
| Refrigerant oil | VG75 44 oz |
| Outdoor fan motor Qty | 2 |
| RLA | 2.2 A |
| Speed | 850/750/650 r/min |
| Outdoor air flow (Max) | 4,237.9 CFM |
| Outdoor noise level (Max) | 64.5 dB(A) |
| Throttle type | EXV+Throttle valve |
| Outdoor unit Dimensions (WxDxH) | 37.48 x 16.34 x 52.48 inch |
| Refrigerant Type | R454B |
| Precharge | 25 ft |
| Additional charge for 1/4 inch liquid pipe | / oz |
| Additional charge for 3/8 inch liquid pipe | 0.32 oz |
| Refrigerant piping Liquid side/Gas side | 3/8"/3/4" inch |
| Max. pipe length | 246 ft |
| Max. difference in level | 98.4 ft |
| Ambient temperature Cooling | -22 ~ 122 F |